Should I use an iron angle or an iron plate to support ...

    https://diy.stackexchange.com/questions/40195/should-i-use-an-iron-angle-or-an-iron-plate-to-support-brick-above-window
    An opening has been cut in my brick wall to make room for a new window. The wall is not structural. The house is framed with wood like most houses here in Dallas Tx. The window is only 30 inches wide. There will be only 5 runs of brick above window. Do I use an angle or just a 3/8" plate as header to support the weight of brick above window?

What size angle iron (steel lentil) do I need to support a ...

    https://www.justanswer.com/structural-engineering/bd3mq-size-angle-iron-steel-lentil-need-support.html
    Jun 27, 2018 · What size angle iron (steel lentil) do I need to support a brick opening 10' wide with 1 story above. It's a non load bearing wall. Tutor's Assistant: OK. Tell me a bit more about what's going on so we can help you best.4/5(8.9K)

Laying brick on top of Steel angle iron - YouTube

    https://www.youtube.com/watch?v=nW8d971l6nY
    Mar 27, 2016 · This is a video of a brick repair the steel above the air conditioner was rotted so we replaced the steel and now laying the Old Brick back in ... Laying brick on top of Steel angle iron francis ...Author: francis sciarrillo

Lintel beam supporting brick front over garage door ...

    https://www.bobvila.com/posts/36980-lintel-beam-supporting-brick-front-over-garage-door
    For example, an angle iron supporting one or two layers of brick and simply fastened into the wooden framework of a house via lag screws, CAN be all that is structurally needed to comply with all ...

Details for Exterior Brick Masonry Veneer Supported by ...

    http://support.sbcindustry.com/images/technotes/T-BrickVeneer09.pdf
    Metal plate connected wood trusses can effectively support brick masonry veneer walls as long as brick veneer is supported by a steel lintel angle that is properly designed, detailed and attached to the truss members. The steel lintel must be bolted to the structural gable truss vertical members as recommended in Figures 2 and 3. This detail ...

Brick Veneer On Steel Angle Iron - Construction ...

    https://www.contractortalk.com/f4/brick-veneer-steel-angle-iron-24300/
    Jul 15, 2007 · In lieu of making a footing 30 inches for the brick, I was going to attach angle iron to the structure and start laying the brick on that. What does it mean that the angle has to be bolted to double studs? I was just going to bolt to my rim joist. Here is what the code says: 1). R703.7.2.1 Support by a steel angle: The minimum size for steel