Blood Pumps For Circulatory Support

Find all needed information about Blood Pumps For Circulatory Support. Below you can see links where you can find everything you want to know about Blood Pumps For Circulatory Support.


CentriMag Circulatory Support System - P170038 FDA

    https://www.fda.gov/medical-devices/recently-approved-devices/centrimag-circulatory-support-system-p170038
    The CentriMag Circulatory Support System includes a blood pump, a motor that drives the pump, a console that controls the motor, a monitor, a flow probe, and flexible tubes (cannulae).

CentriMag Circulatory Support System Abbott

    https://www.cardiovascular.abbott/us/en/hcp/products/heart-failure/centrimag-acute-circulatory-support-system.html
    PediMag™ Blood Pump Indications for Use [510(k) Clearance; 6-hour use]: The PediMag Blood Pump is indicated for use with the CentriMag Circulatory Support System console and motor to pump blood through the extracorporeal bypass circuit for extracorporeal circulatory support for periods appropriate to cardiopulmonary bypass (up to six hours) for surgical procedures such as mitral valve reoperation. It is also indicated for use in extracorporeal support …

Home isrbp Website! - isrbp Website!

    https://www.ismcs.org/
    The International Society for Mechanical Circulatory Support (formerly the International Society for Rotary Blood Pumps)

Blood pumps for circulatory support - Helmut M Reul ...

    https://journals.sagepub.com/doi/10.1177/026765910001500404
    Jul 01, 2000 · Noon GP , Bull JW Jr , Short HD et al. Bio-Medicus centrifugal ventricular support for postcardiotomy cardiac failure: a review of 129 cases . Ann Thorac Surg 1996; 61: 291 - 295 . Yamazaki K , Litwak P , Tagusari O et al. An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal System)...Cited by: 76

Centrimag Blood Pump - Perfusion.com

    https://www.perfusion.com/product/centrimag-blood-pump/
    CentriMag™ Blood Pump Indications [510(k) Clearance; 6-hour use]: The Abbott CentriMag Blood Pump is indicated for use only with the Thoratec CentriMag Console to pump blood through the extracorporeal bypass circuit for extracorporeal circulatory support for periods appropriate to cardiopulmonary bypass (up to six hours). It is also indicated for use in extracorporeal support systems (for periods up to six hours) not requiring complete cardiopulmonary …

Abbot Recalls CentriMag Circulatory Support System Motor ...

    https://www.fda.gov/medical-devices/medical-device-recalls/abbot-recalls-centrimag-circulatory-support-system-motor-due-pump-and-motor-issues
    The system also provides temporary blood circulatory support for up to 30 days for patients in cardiogenic shock when the right side of the heart loses pumping power, and blood backs up in the ...

Blood Pumps for Circulatory Support - ResearchGate

    https://www.researchgate.net/publication/12394820_Blood_Pumps_for_Circulatory_Support
    Damage of red blood cells (hemolysis) in miniaturized pump systems for heart support is induced by contact with artificial surfaces and high mechanical shear forces.

Blood pumps for circulatory support.

    https://www.ncbi.nlm.nih.gov/pubmed/10926412
    Blood pumps for circulatory support. Reul HM(1), Akdis M. Author information: (1)Cardiovascular Biomechanics Group, Helmholtz-Institute for Biomedical Engineering at the Aachen University of Technology, Germany. [email protected] by: 76

Mechanical Circulatory Support for Advanced Heart Failure ...

    https://www.ahajournals.org/doi/10.1161/circulationaha.111.060830
    The field of circulatory support has matured dramatically in recent years, thanks to the advent of smaller, rotary pumps. The resulting transition away from older pulsatile devices has been swift. Accelerated use of continuous-flow left ventricular assist devices (LVADs) for long-term support has changed the face of advanced heart failure care.Cited by: 187

What is hemolysis and why do mechanical heart pumps cause ...

    https://www.protectedpci.com/faq/do-mechanical-heart-pumps-cause-hemolysis/
    Hemolysis is a consequence of blood movement through mechanical circulatory support (MCS) devices. RBCs experience high shear force as they pass through narrow openings in MCS devices. The RBCs traveling through unobstructed regions, such as regions away from the cannula wall, travel at higher speeds compared to RBCs in contact with the cannula wall.