Dec 19, 2007 · Article 760.8 requires that fire alarm cables and conductors be supported by the building structure. I would like to hear what others think regarding supporting the fire alarm cables from the suspended ceiling support wires. Tony
http://www.mikeholt.com/download.php?file=PDF/Fire_Alarm_Systems_2014NEC.pdf
Mike Holt’s Illustrated Guide to. ... Abandoned Fire Alarm Cable. ... When a raceway is used for the support or protection of cables, a bushing to reduce the potential for abrasion must be placed at the location where the cables enter the raceway in accordance with 300.15(C). Figure 760–7
https://www.prospertx.gov/wp-content/uploads/NFPA-NEC-Guide-to-Wire-Box-Installation-02-17.pdf
IFC/NFPA/NEC Guide to Fire Alarm Wiring & Box Installations ... Direct-buried cable or conduit or other raceways shall be installed to meet the ... 760.143 Support of Conductors. Power-limited fire alarm circuit conductors shall not be strapped, taped, or attached
https://electrical.theiet.org/wiring-matters/years/2015/58-autumn-2015/fire-performance-of-cable-supports/
Support 3: Passivated stainless steel cable support with fold over fastening tabs for use with 2 core 1.5 mm 2 fire alarm cables. The support meets the requirements of BS 5839-1. Support 4: Double cable saddle support for 2 core 1.5 mm 2 fire alarm cable. This support was made of copper and coated with a polymeric coating.
https://www.eng-tips.com/viewthread.cfm?qid=444672
The NEC does not distinguish supports of fire alarm cable vs other systems so j-hooks or whatever supports are used are regulated by NFPA 70 not NFPA 72. Typical spacing for cable or conduit supports is 10-ft, but not everything. For instance, MC Cable whips are limited to a …
https://www.mikeholt.com/mojonewsarchive/NEC-HTML/HTML/Article760FireAlarmSignalingSystems~20030106.htm
Article 760 - Fire Alarm Signaling Systems. ... fire-stop material per the specific instructions supplied by the manufacturer of the specific type of cable and construction material. When you make ... You must provide support at intervals of not more than 18 in., if the cables are within 7 ft of the floor. ...
http://info.belden.com/hubfs/ESD-Assets/Product-Pages/Copper/Cable/safety-fire-alarm-cables.pdf
• Fire Alarm • Audio Circuits • Control Circuits • Initiating Circuits • Notification Circuits Stranding No. of Cond. Ft. m Standard Lengths kg Inch mm Standard Unit Weight Outer Jacket Thickness Nominal OD Lbs. Inch mm Fire Alarm Cable NPLF Systems Unshielded or Shielded, Non-Power-Limited Signaling Cable Part No. Unshielded Multi ...
https://www.thecablingcompany.com/news/regulations-for-fire-resistant-cable-supports-what-you-need-to-know
Regulations For Fire Resistant Cable Supports - What You Need To Know! Written on 19 January 2016.. This new amendment is nearing its final stages of release and it follows 2013's Second Amendment.
Need to find Fire Alarm Cable Support information?
To find needed information please read the text beloow. If you need to know more you can click on the links to visit sites with more detailed data.