Support for Luminaires/Light fixtures etc.

    https://www.electrical-contractor.net/forums/ubbthreads.php/topics/172419/all/Support_for_Luminaires_Light_f.html
    Jan 09, 2008 · MA. Code. Any fixture with a ballast needs additional support. 410.16 (C)-- Add second paragraph. "In addition to,or in lieu of,the machanical means,electrical fixtures containing ballasts,other than simple flourescent reactance ballasts,shall be supported directly to the building structure by wire,chain or threaded rod of sufficiantstrength to carrythe fixture.Flourescent fixtures shall be ...

Where the red wire goes in a light fixture

    https://dfarq.homeip.net/where-the-red-wire-goes-in-a-light-fixture/
    Nov 24, 2015 · If you change a light fixture and find a red wire in the electrical box, chances are the black wire from the fixture needs to go to the red wire in the box. Normally you’ll see a red wire in places you would expect a ceiling fan.

Code Q&A EC&M

    https://www.ecmweb.com/national-electrical-code/qa/article/20887010/code-qa
    The ceiling-support wires or ceiling grid must not be used to support raceways and cables (power, signaling, or communications). However, independent support wires that are secured at both ends and provide secure support are permitted [300.11(A)].

Attaching M.C. cable to wire that is supporting the drop ...

    https://www.electriciantalk.com/f30/attaching-m-c-cable-wire-supporting-drop-ceiling-41789/
    Aug 10, 2012 · Here it goes by jurisdiction but most want out tie wire separate from the ceiling grid wire. This is for MC or light fixtures, etc. The areas that want seperate support want it because the firemen like to chop ceilings first and ask questions later and some have dropped fixtures or whole ceilings on themselves fighting a fire.

lay-in fixtures, independent support wires....

    https://www.electrical-contractor.net/forums/ubbthreads.php/topics/184969/all/lay_in_fixtures_independent_su.html
    Jan 07, 2011 · In addition to, or in lieu of, the mechanical fastening means, electric luminaires (fixtures) containing ballasts, other than simple fluorescent reactance ballasts, shall be supported directly to the building structure by wire, chain, or threaded rod of sufficient strength to carry the luminaire (fixture).

What Is the Red Wire for When Installing a Light Fixture ...

    https://homeguides.sfgate.com/red-wire-installing-light-fixture-66927.html
    Dec 15, 2018 · The exact purpose of a red wire for a light fixture can vary. Except in rare cases, it is a hot wire or a switched hot wire. Check the wire with a non-contact voltage tester with the power and switch turned on. If the tester indicates the wire is hot, turn the switch off and retest.

Light Fixture Wiring and the Spare Red Wire

    https://ask-the-electrician.com/light-fixture-wiring-and-the-spare-red-wire/
    The Red Wire in the Ceiling Fan or Light Fixture Wiring Electrical Question: I am trying to replace a ceiling light fixture. The switch it is connected to is a dimmer switch with an on/off button as well as a dimmer slider. The wiring in the ceiling contains a black, red and white wire as well as a ground. The fixture contains only black and white.

6.4 MECHANICAL, ELECTRICAL, AND PLUMBING …

    https://www.fema.gov/sites/default/files/orig/plan/prevent/earthquake/fema74/pdf/chapter6_4_9/chapter6_4_9_1.pdf
    o For fixtures weighing from 10 lb to 56 lb, provide two #12 safety wires at diagonally opposite corners connected from the fixture housing (not the detachable end plates) to the structure above; wires …

9 Common Wiring Mistakes and Code Violations

    https://www.finehomebuilding.com/membership/pdf/20751/021190076.pdf
    fixtures are made with 90°C wires, which means the wire inside the fixture is rated to operate safely at temperatures up to 90°C. Problems occur when you connect the new fixture to old wires in the house. Most homes built before 1987 were wired with 60°C con-ductors; the new fixture can create heat that