https://www.enggcyclopedia.com/2012/06/spacing-pipe-supports/
For example, the spacing of pipe supports on a 6" line will be approximately 6 + 10 = 16 feet. This spacing changes at high temperatures and for materials other than steel. For example, for copper tubing, support spacing varies from 8-ft for 1" tubing to 12-ft for 4". For PVC pipe the spacing depends on the pipe schedule and operating temperature.
https://www.engineeringtoolbox.com/piping-support-d_362.html
Epoxy Pipes - Support Spacing - Support spacing for reinforced Epoxy fiberglass pipes; Piping Elbows - Thrust Block Forces - Thrust block forces on pipe bends anchor due to liquid velocity and internal pressure - online resulting force calculator; PP Pipes - Support Spacing - Maximum distance between PolyPropylene pipes supports
https://www.guenthersupply.com/pdf/hanger-spacing-weight-chart.pdf
* Many codes require pipe hangers to be spaced every 10 ft. regardless of 1 Cubic Ft. of water weighs 62.41 lbs. size. Check local codes. 1 gallon (U.S.) weighs 8.335 lbs. Spacing and capacities are based on water filled pipe. Closer hanger spacing may be required where …
http://www.wermac.org/steel/pipesupports_spacing.html
The spacing is based on a fixed beam support with a bending stress not exceeding 2,300 psi (15.86 MPa) and insulated pipe filled with water or the equivalent weight of steel pipe for steam, gas, or air service, and the pitch of the line is such that a sag of 0.1 in. (2.5 mm) between supports is permissible.
http://www.inspect2code.com/2015-residential-code-for-gas-pipe-support/
The 2015 Residential Code requires gas pipe support both vertically and horizontally. Horizontal support spacing distances vary by pipe diameter and can be found in table G2424.1. The distance varies anywhere from six to ten feet depending on pipe diameter.
https://www.ridgidforum.com/forum/mechanical-trades/ask-the-plumbing-experts/17600-gas-pipe-support-code-requirements
Re: Gas pipe support code requirements Michigan uses the International code series. I would use the most stringent requirement to be on the safe side. International Fuel gas code 2006- section 415 Table 415.1 states:" Steel pipe 3/4 or 1 inch shall have spacing of supports @ 8 foot "
http://www.piping-engineering.com/minimum-pipe-spacing-chart.html
Minimum Pipe Spacing Chart. 2 Comments. In petrochemical & refinery plants there are many pipes which are running from source to destination. In most of the cases there is pipe rack between the plant units which carry these pipes and distribute it across the plant.
http://www.performancepipe.com/en-us/Documents/PP901%20Field%20Handbook%20WEB%20VERSION.pdf
The Performance Pipe . Field Handbook . NOTICE This Field Handbook contains selected information that is excerpted and summarized from the PPI Handbook for Polyethylene Pipe and Performance Pipe literatures. This handbook is a quick reference aid. The user should review the original source of publication which are all available at
https://www.engineeringtoolbox.com/steel-pipe-supports-d_1071.html
Recommended distance between steel pipe supports . Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications! ... Hanger Support Spacing - Rod Sizes Horizontal Pipes - Recommended maximum support span between hangers - and rod sizes for straight horizontal pipes;