https://forums.mikeholt.com/threads/light-fixture-supports-in-suspended-ceilings.48963/
May 16, 2008 · From the old NEC: NEC, 1984, 410-16(c) Suspended Ceilings. Framing members of suspended ceiling systems used to support fixtures shall be securely fastened to each other and shall be securely attached to the building structure at appropriate intervals.
https://www.ecmweb.com/national-electrical-code/article/20891486/code-qa
Can recessed or surface-mounted lighting fixtures be supported by securing them to the suspended ceiling grid, or must they be independently supported from the building structure? A. The NEC does not specify that suspended ceilings can be used for the support of luminaries.
https://www.justanswer.com/electrical/4mkbn-electrical-code-lighting-fixture-supports.html
Feb 21, 2011 · Dear Sir, Kindly advise for the requirement of the bathroom light fixtures as per NEC( if it should be IP rated ) and in which section of our great NEC I can find your answer Your kind great help will …
https://www.electrical-contractor.net/forums/ubbthreads.php/topics/184969/all/lay_in_fixtures_independent_su.html
Jan 07, 2011 · The National Electric Code is the Code I was hired to enforce. Nothing in that Code has me asking the electrician to install any additional wires or jack chain or aircraft cable. ... this is where these building inspectors get their nebulous understanding of why additional wires are required on lay-in light fixtures. Very few, if any ...
https://iaeimagazine.org/magazine/2015/marchapril-2015/nec-article-410-luminaires-lampholders-and-lamps/
Photo 2. Here is a pendant fixture I noticed while in a bookstore in San Francisco. I know they have a tendency to experience seismic action on a regular basis, but I don’t think this is the proper method of support for seismic shock absorption. By the way, this wasn’t the only one, there were several fixtures all in the same condition.
https://www.electrical-contractor.net/forums/ubbthreads.php/topics/172419/all/Support_for_Luminaires_Light_f.html
Jan 09, 2008 · MA. Code. Any fixture with a ballast needs additional support. 410.16 (C)-- Add second paragraph. "In addition to,or in lieu of,the machanical means,electrical fixtures containing ballasts,other than simple flourescent reactance ballasts,shall be supported directly to the building structure by wire,chain or threaded rod of sufficiantstrength to carrythe fixture.Flourescent fixtures shall be ...
http://www.efficientlightingsupply.com/nec-codes-i-29.html
6 inches for fluorescent fixtures. NEC 410-8 - Storage space, as applied to an electrical installation in a closet, is defined in the National Electrical Code as a volume bounded by the sides and back closet walls and planes extending from the closet floor vertically to a height of 6 feet (1.83m) or the highest clothes-hanging rod and parallel ...