Progress Technical Support 748

Find all needed information about Progress Technical Support 748. Below you can see links where you can find everything you want to know about Progress Technical Support 748.


Progress KB - Corrective Measures for Error 748.

    https://knowledgebase.progress.com/articles/Article/P2916
    Select 2. Activity Displays -> 1. Summary and then press s for a sampling. Once the sampling occurs, then type X to exit. If the number of servers have been exhausted, then there may be a need to alter the database startup parameters to accommodate more servers per broker.

Progress KB - Error 748 occurs when database has been ...

    https://knowledgebase.progress.com/articles/Article/P184454
    The -Mp parameter (Servers Per Protocol) is restricting the number of Servers that can be started for the TCP Protocol.For example, if -Mp 2 is used, depending on the order of which connection type are made to the database, either 2 ABL, 2 SQL or one Remote Server of each Type are configured to start. The legacy Servers per Protocol (-Mp) parameter remains from the time when Progress supported ...

Progress KB - How to investigate errors (748) and (1334)

    https://knowledgebase.progress.com/articles/Article/P3415
    How to investigate errors (748) and (1334) Suggestions for troubleshooting the root cause of errors "The server or the system has no more resources. Please contact Progress Technical Support. (748)" and "Rejecting login -- too many users for this server. (1334)".

Progress KB - Error 748 occurs when connecting to a ...

    https://knowledgebase.progress.com/articles/Article/P133032
    1. Configure the database broker to have multiple login brokers (1 for 4GL clients and 1 for SQL clients). 2. Ensure that the database startup parameters are configured to address the remote server processes as well as the number of clients connecting to them.

Progress KB - 4GL client cannot connect to a database due ...

    https://knowledgebase.progress.com/articles/Article/P135797
    The server or the system has no more resources. Please contact Progress Technical Support. (748) ** Server rejected login. (700)

Progress KB - Remote clients cannot connect to database ...

    https://knowledgebase.progress.com/articles/Article/P132208
    The server or the system has no more resources. Please contact Progress Technical Support. (748) No servers are available. Try again later. (1154) Disconnected from server because database name was incorrect. (437) ** Server rejected login. (700) Server cannot find a free port for a TCP socket. (1159) 4GL server process terminated. (8837)

Support and Learning Resources - Progress

    https://www.progress.com/support
    Support and Learning. Find tutorials, documentation, troubleshooting articles, training resources and more for your Progress products and solutions.

Progress KB - OE Architect application fails to connect to ...

    https://knowledgebase.progress.com/articles/Article/P138520
    When trying to run an application in OE Architect, it fails to connect to the database(s) with error: "(748) the serve or system has no more resources"



Need to find Progress Technical Support 748 information?

To find needed information please read the text beloow. If you need to know more you can click on the links to visit sites with more detailed data.

Related Support Info