Find all needed information about Progress Technical Support 748. Below you can see links where you can find everything you want to know about Progress Technical Support 748.
https://knowledgebase.progress.com/articles/Article/P2916
Select 2. Activity Displays -> 1. Summary and then press s for a sampling. Once the sampling occurs, then type X to exit. If the number of servers have been exhausted, then there may be a need to alter the database startup parameters to accommodate more servers per broker.
https://knowledgebase.progress.com/articles/Article/P184454
The -Mp parameter (Servers Per Protocol) is restricting the number of Servers that can be started for the TCP Protocol.For example, if -Mp 2 is used, depending on the order of which connection type are made to the database, either 2 ABL, 2 SQL or one Remote Server of each Type are configured to start. The legacy Servers per Protocol (-Mp) parameter remains from the time when Progress supported ...
https://knowledgebase.progress.com/articles/Article/P3415
How to investigate errors (748) and (1334) Suggestions for troubleshooting the root cause of errors "The server or the system has no more resources. Please contact Progress Technical Support. (748)" and "Rejecting login -- too many users for this server. (1334)".
https://knowledgebase.progress.com/articles/Article/P133032
1. Configure the database broker to have multiple login brokers (1 for 4GL clients and 1 for SQL clients). 2. Ensure that the database startup parameters are configured to address the remote server processes as well as the number of clients connecting to them.
https://knowledgebase.progress.com/articles/Article/P135797
The server or the system has no more resources. Please contact Progress Technical Support. (748) ** Server rejected login. (700)
https://knowledgebase.progress.com/articles/Article/P132208
The server or the system has no more resources. Please contact Progress Technical Support. (748) No servers are available. Try again later. (1154) Disconnected from server because database name was incorrect. (437) ** Server rejected login. (700) Server cannot find a free port for a TCP socket. (1159) 4GL server process terminated. (8837)
https://www.progress.com/support
Support and Learning. Find tutorials, documentation, troubleshooting articles, training resources and more for your Progress products and solutions.
https://knowledgebase.progress.com/articles/Article/P138520
When trying to run an application in OE Architect, it fails to connect to the database(s) with error: "(748) the serve or system has no more resources"
Need to find Progress Technical Support 748 information?