https://www.familyhandyman.com/walls/how-to-install-a-loadbearing-beam/
In fact, removing the wall and replacing it with a beam will only take a half day or less. We’ll show you how to build a temporary support wall to hold up the floor above while you tear out the old wall (Photos 1 – 7). Then we’ll show you how to create the beam supports at each end (Photos 6, 7 and 11).Author: The Family Handyman
https://www.hunker.com/13403225/how-to-replace-a-load-bearing-wall-with-a-beam
The bearing points for the new beam must transfer the weight all the way to the foundation, which means the engineer might require additional post support in floors beneath the bearing posts. When replacing a basement wall, it might be possible to cut beam "pockets" in the top of the foundation wall to support the new beam.
https://www.homeadvisor.com/cost/additions-and-remodels/remove-load-bearing-wall/
Replace a Load-bearing Wall with a Beam Cost Costs to install a steel beam range from $1,150 to $4,600, but will vary based on the size and type of steel beam you choose and the labor needed to install it. The more popular and cost-effective option, laminated veneer lumber (LVL) beams, ranges in price from $55 to $400, not including installation.
https://www.finehomebuilding.com/2015/07/14/how-to-install-a-load-bearing-beam
If you want to connect two rooms with a flat ceiling, then you’ll have to replace the wall with a beam hidden in the ceiling. If you want an open cathedral ceiling, you’ll need to bring the beam …
https://www.youtube.com/watch?v=poBtAmMwXzE
Feb 14, 2017 · LVL beams are available in smaller sizes that can be easily hauled to a location by hand, and screwed together to form a larger member that will meet requirements to carry a load. Category ...Author: DunnLumber1907
http://www.howtobuildahouseblog.com/us-a-suitable-beam-size-for-removing-load-bearing-wall/
Aug 17, 2011 · Structural Support: However, if you wish to remove an internal wall, or form an opening in an internal wall, building regulations will normally apply. Before removing a load-bearing wall, a structural engineer or surveyor can be employed to determine if the wall is load bearing and then design a beam to cater for these loads.
https://www.houzz.com/discussions/340419/how-much-costs-to-put-a-support-beam-after-removing-a-14-foot-wall
Feb 07, 2013 · $2500, would be on the low side for load bearing wall/ beam install, there are a couple variables beam size and dimensions, the span is key, your structural engineer will calculate.The beam size and options for the beam, lvl, glulam ect.. I am putting up a 19' ft 9-1/2" 2ply lvl beam …