Attaching Electrical Cables to Framing Members

    https://www.thespruce.com/securing-electrical-cables-1152891
    General Cable Support Runs of NM cable must be supported at least every 54 inches. They also must be secured within 12 inches of an electrical box that includes a cable clamp or within eight inches of a box or enclosure without a cable clamp. Keep in mind that "support" does not always mean fastening the cable to framing.

Maximum allowable distance between supports for temporary ...

    https://www.osha.gov/laws-regs/standardinterpretations/2004-05-13
    May 13, 2004 · "Romex" is the trade name of a specific type of cable. The electrical classification for Romex-style cable is non-metallic sheath cable. The 1984 National Electrical Code stated that, in additional to code sections that specifically address temporary wiring, all requirements of the 1984 Code for permanent wiring also apply to temporary wiring.

NM Stackers & spacing - Electrician Talk - Professional ...

    https://www.electriciantalk.com/f2/nm-stackers-spacing-21107/
    Feb 21, 2011 · So I was teaching my apprentice class the other night... we usually start the class off with code questions or jobsite questions that the apprentices have come up with over the work week. Someone asked me about bundling NM cables and derating issues. Their question was if romex Stackers (stack-its, whatever) adequately maintain spacing.

Stapling Romex - Electrical - DIY Chatroom Home ...

    https://www.diychatroom.com/f18/stapling-romex-35617/
    Jan 12, 2009 · I don't used romex much in detached garage in resdentail area but if on farm area all bets is off have to run with either EMT or PVC depending on the set up. But if you see on my side in France everything have to be enclosed no exposed cable like romex showing. Merci,Marc 01 …

Installation Guidelines for Non-Metallic-Sheathed Cable ...

    https://www.cityofpensacola.com/DocumentCenter/View/100/Installation-Guidelines-for-Non-Metallic-Sheathed-Cable-Romex-PDF?bidId=
    Installation Guidelines for Non-Metallic-Sheathed Cable (Romex) Note: Number 14 is missing a number 1. Bored holes MUST BE 1 1/4 inch from the edges of any stud or top plate.

Romex running under joist - InspectionNews

    http://www.inspectionnews.net/home_inspection/electrical-systems-home-inspection-and-commercial-inspection/12422-romex-running-under-joist.html
    Mar 17, 2009 · I found a section in the code that states Romex must run through joists and not be stapled to the underside. Does this include crawl space installations. Romex in photos is hanging along the underside of some joists and running through punch outs in others. The whole thing is a …

What are the requirements for wiring staples, distance ...

    https://www.justanswer.com/home-improvement/13xpe-requirements-wiring-staples-distance.html
    NM cable (Romex) is to be supported every 4 1/2 feet and within 12 inches of a box. I hope that this has been helpfull .. if it has please click on the accept button ... PLEASE take a minute to leave me feedback .. Thats how I know how well I am doing .. and if I really hit it …

2011 NEC Revisions for Cable EC&M

    https://www.ecmweb.com/national-electrical-code/code-basics/article/20896213/2011-nec-revisions-for-cable
    If you install multiple Type NM cables in contact with thermal insulation without maintaining spacing between cables, then you must adjust the allowable ampacity of each conductor per Table ... or panelboards or support structures (for example, concrete pads) can’t extend more than 6 in. beyond the front of the electrical equipment [Sec. 110 ...