Seismic Duct Support Detail

Find all needed information about Seismic Duct Support Detail. Below you can see links where you can find everything you want to know about Seismic Duct Support Detail.


SMACNA Seismic Restraint Manual - iccsafe.org

    http://media.iccsafe.org/news/annual_conference/2013-AtlanticCity/documents/Seismic_Restraint.pdf
    Seismic supports are not required for HVAC ductwork when the I p = 1.0 if either of the following conditions is met for the entire duct run: 1. Ducts are suspended from hangers 12 in. or less as measured from the top of the duct to the bottom of the support where

KINETICS™ Pipe & Duct Seismic Application Manual

    https://www.kineticsnoise.com/seismic/pipe_duct/installation.pdf
    Seismic restraints for pipe and duct are generally separated into to two categories. 1. Transverse Seismic Restraints: These act to keep the pipe or duct from swinging side-to-side. They are normally placed so that they act perpendicular, at right angles, to the pipe or ... KINETICS™ Pipe & …

Support Sample Drawings - Autocad Details

    http://autocaddetails.net/cad_directory/commercial_pdf/HTRW/Supports/Supports.htm
    Pipe & Suspended Equip. Support from Metal Deck.dwg. 19. Pipe & Suspended Equip. Support from Metal Deck.pdf: 20. 20. Wall Anchor.dwg ... Manhole Seismic Detail.dwg. 34. Manhole Seismic Detail.pdf ... A collection of over 9,230+ 2D construction details and drawings for residential and commercial application. One Hundred Twenty major categories ...

Duct Support Duct Supports

    https://www.phpsd.com/rooftop-support-systems/duct-supports
    PHP-D Duct Support. The PHP-D duct support leverages a goal-post design with a single crossbar below the duct to support all sizes of square or round ducting, cable trays, and piping. This support can meet nearly all height requirements above the roof surface and is …

Guidelines for Seismic Verification of HVAC Duct and ...

    https://repository.lib.ncsu.edu/bitstream/handle/1840.20/31311/K16_4.pdf?sequence=1&isAllowed=y
    The guidelines rely on the evaluation of seismic failure mechanisms for duct and damper systems from seismic experience data presented in Appendices A and B and seismic test data presented in Appendix D of [1]. The data show that damage to duct systems is generally limited to direct seismic damage of the duct or supports, or indirect damage due to

Installing Seismic Restraints for Duct and Pipe FEMA.gov

    https://www.fema.gov/media-library/assets/documents/848
    Jan 01, 2004 · Installing Seismic Restraints for Duct and Pipe. Print Publication (Hardcopy) Distribution Warehouse. Publication Number: FEMA 414. You can order this item from the FEMA Distribution Center.

Seismic Bracing Systems - Unistrut Service Company

    https://www.unistrutohio.com/wp-content/uploads/pdf/library/unistrut-seismic-bracing-for-1998-cbc.pdf
    All ducts suspended by hangers 12 inches or less in length from the top of the duct to the bottom of the support for the hanger. 5. Unistrut nuts and bolts mounted to the Unistrut channels shall be tightened to the ... Including Horizontal Seismic Force of .50 G Pipe Max.Support Weight Of Horizontal Seismic Pipe Section Spacing Per Pipe Plus ...

STANDARD DETAILS (PG-18-4) - Office of Construction ...

    https://www.cfm.va.gov/TIL/sDetail.asp
    The links toward the top of the page are navigational, and allow the user to jump to the desired section in the formatting table below that contains the details. The columns in the formatting table indicate the detail number, the title of the detail, and provide the link to the file indicating the file type extension.

BROCHURE - Unistrut

    https://unistrut.co.nz/catalogue/Unistrut_Seismic_Bracing.pdf
    the installation of the seismic bracing system. The Seismic Tables are for a seismic factor of 1.0g and can be used to determine brace location, sizes, and anchorage of pipe/duct/conduit and trapeze supports. The development of a new seismic table is required for seismic factors other than 1.0g and must be reviewed by OSHPD prior to seismic ...

VA Standard Details - Div 23 HVAC Steam - All Details 1 of 2

    https://www.cfm.va.gov/til/sDetail/sDetail-Div23-PDF-1.pdf
    supply duct (up & down) exhaust duct (up & down) ... date issued: cad detail no.: detail title /support anchor (condenser water or chilled water) december 2008 sd230511-26.dwg none # ... detail title /piping crossing a seismic joint detail "e" december 2008 sd230511-33.dwg none

SMACNA Seismic Restraint Manual - iccsafe.org

    http://media.iccsafe.org/news/annual_conference/2013-AtlanticCity/documents/Seismic_Restraint.pdf
    The SMACNA Seismic Restraint Manual has tables for four values of C s ... Details provide lateral bracing system. Typical vertical supports per local building code must be used. 2. Thermal expansion not given but ... of the duct to the bottom of the support where . Bracing of Ducts the hanger is attached. Hangers must be

Seismic Bracing Systems - Unistrut Service Company

    https://www.unistrutohio.com/wp-content/uploads/pdf/library/unistrut-seismic-bracing-for-1998-cbc.pdf
    Maximum pipe support spacing should be as per chart 1, row 3 page 3-12. 4. Select trapeze member using the total weight on the trapeze and the length of trapeze required to fit the given pipe sizes and quantities (page 3-1, 3-2, tables 2-5). 5. Calculate horizontal seismic force (Fh) assuming braces on alternate trapeze supports (page 2-2 ...

Fire protection solutions TOLCO hangers and restraints ...

    https://www.eaton.com/us/en-us/products/support-systems/fire-protection-solutions.html
    A critical component of any fire sprinkler system in regions where earthquakes can occur, is a well designed and installed hanging and seismic bracing system. For over 60 years, Eaton has been serving the fire protection industry with its innovative TOLCO seismic bracing products and B-Line series pipe hangers. With exceptional quality and ...

KINETICS™ Pipe & Duct Seismic Application Manual

    https://www.kineticsnoise.com/seismic/pipe_duct/installation.pdf
    Longitudinal Seismic Restraints: These act to keep the pipe or duct from swinging back-and –forth along the length of the pipe or duct. Typically, they are placed parallel to, or along, the length of the pipe or duct, as shown in Figure I1-1.

Guidelines for Seismic Verification of HVAC Duct and ...

    https://repository.lib.ncsu.edu/bitstream/handle/1840.20/31311/K16_4.pdf?sequence=1&isAllowed=y
    place the duct spans within the limits of earthquake experience data: • Duct support to support spans should not exceed 15 feet. • Supports should be provided within 5 feet from fittings such as Tees and Wyes in each branch of the fitting • Duct cantilevered length (beyond end of last support…

Installing Seismic Restraints for Duct and Pipe FEMA.gov

    https://www.fema.gov/media-library/assets/documents/848
    Jan 01, 2004 · Examples of anchoring and seismic restraint devices; attachment types and instructions for installing equipment in different configurations; and special cases for housekeeping pads, cable assemblies, supports for control panels, and residential equipment are included.

Duct Support Duct Supports

    https://www.phpsd.com/rooftop-support-systems/duct-supports
    The PHP-D duct support leverages a goal-post design with a single crossbar below the duct to support all sizes of square or round ducting, cable trays, and piping. This support can meet nearly all height requirements above the roof surface and is approved for seismic and high-wind applications.

Support Sample Drawings - Autocad Details

    http://autocaddetails.net/cad_directory/commercial_pdf/HTRW/Supports/Supports.htm
    U-Bolt Pipe Support.dwg. 01. U-Bolt Pipe Support.pdf: 2. 02. C-Rail PipeSupport.dwg. 02. C-Rail PipeSupport.pdf ... Seismic Details for Sway Bracing.dwg. 29. Seismic Details for Sway Bracing.pdf: 30. 30. ... One Hundred Twenty major categories of fully editable and scalable drawings and details in AutoCad Format. These are a perfect starting ...

Seismic Restraint Systems Guidelines

    http://www.cooperindustries.com/content/dam/public/bline/Resources/Library/catalogs/seismic_restraints/seismic-OSHPD/TOC_9.pdf
    These Seismic Restraint Systems Guidelines show the step by step process Of providing the necessary protection against seismic events for pipe, duct and electrical systems. TOLCO also offers total seismic services including brace layout, engineering calculations and stamp where

STANDARD DETAILS (PG-18-4) - Office of Construction ...

    https://www.cfm.va.gov/TIL/sDetail.asp
    The links toward the top of the page are navigational, and allow the user to jump to the desired section in the formatting table below that contains the details. The columns in the formatting table indicate the detail number, the title of the detail, and provide the link to the file indicating the file type extension.