https://www.asme.org/topics-resources/content/seismic-protection-for-pressure-piping-systems
Proper seismic detailing for suspended pipes requires both transverse and longitudinal braces, installed at spacing intervals that depending primarily on the level of seismic activity at the building site, location within the building, pipe size and type, and the strength of the connections to the structure.
https://www.unistrutohio.com/wp-content/uploads/pdf/library/unistrut-seismic-bracing-for-1998-cbc.pdf
If necessary, seismic force can be recalculated with braces on every trapeze (see figure 2). Pipe Data Table 1 Data for Schedule 40 Standard Weight Pipe Including Horizontal Seismic Force of .50 G Pipe Max.Support Weight Of Horizontal Seismic Pipe Section Spacing Per Pipe Plus Force/Ft. of Pipe Size Modulus ASME B31.1* Water (.5 x Pipe Wt./Ft.)
https://www.fema.gov/media-library/assets/documents/848
Jan 01, 2004 · Installing Seismic Restraints for Duct and Pipe. ... (FEMA 413), and duct and pipe (FEMA 414) to buildings to minimize earthquake damage. The guides describe various types of equipment and include a chart that identifies the types of recommended equipment, the configuration for restraint, and the type of attachment needed. ...
https://www.eaton.com/us/en-us/products/support-systems/fire-protection-solutions.html
A critical component of any fire sprinkler system in regions where earthquakes can occur, is a well designed and installed hanging and seismic bracing system. For over 60 years, Eaton has been serving the fire protection industry with its innovative TOLCO seismic bracing products and B-Line series pipe hangers. With exceptional quality and ...
https://www.kineticsnoise.com/seismic/pipe_duct/installation.pdf
Seismic restraints for pipe and duct are generally separated into to two categories. 1. Transverse Seismic Restraints: These act to keep the pipe or duct from swinging side-to-side. They are normally placed so that they act perpendicular, at right angles, to the pipe or ... KINETICS™ Pipe & Duct Seismic Application Manual The ...
http://www.seismicresilience.org.nz/topics/non-structural-systems/restraining-engineering-systems/restraining-piping-systems/
All piping systems with pipes greater than 200 mm in diameter require specifically designed restraints. For installations with a gas consumption exceeding 700 kW, the design should include a seismically operated shut-off valve.