Lun 0 Does Not Support Alua

Find all needed information about Lun 0 Does Not Support Alua. Below you can see links where you can find everything you want to know about Lun 0 Does Not Support Alua.


ESXi does not follow iSCSI ALUA path selection ... VMware ...

    https://communities.vmware.com/thread/617879
    Sep 06, 2019 · LUNs are owned by one Storage controller on the array. From an ESXi point of view you speak of active or "passive" paths, not LUN. I worked with a couple of Dell ALUA arrays and never had the issue you are facing. Does the documentation of the product you use include configuration for ESXi? Can you get support from them?

Asymmetric Logical Unit Access (ALUA) support on NetApp ...

    https://kb.netapp.com/app/answers/answer_view/a_id/1003251/~/asymmetric-logical-unit-access-%28alua%29-support-on-netapp-storage---frequently
    Nov 27, 2017 · For example, ALUA is not supported for VMware ESX until vSphere 4.0. Check with the host OS vendor for supportability. Check the host system for any script that might be managing the paths automatically and disable it.

Mixing FC and iSCSI paths - NetApp

    https://library.netapp.com/ecmdocs/ECMP1307349/html/GUID-B0BBC09F-A1E8-409E-8FEA-429894C9E17C.html
    The DSM does not support both FC and iSCSI paths to the same LUN for Data ONTAP operating in 7-Mode. Note: FC refers to traditional Fibre Channel and Fibre Channel over Ethernet (FCoE). Because ALUA is required for FC paths, and ALUA is not supported for iSCSI paths to 7-Mode LUNs, the DSM does not support both FC and iSCSI paths to the same 7-Mode LUN.

ALUA ALUA Definition Pearson IT Certification

    http://www.pearsonitcertification.com/articles/article.aspx?p=2819032
    Oct 05, 2017 · This means that the storage array does not support ALUA or, in the case of EMC CLARiiON, the initiator records are not configured in a mode that supports ALUA. Implicit—The array responds to REPORT TPGs but not SET TPGs commands. In this case, setting the TPG’s AAS is done only by the storage array.

ALUA MPIO Test (LOGO) Microsoft Docs

    https://docs.microsoft.com/en-us/windows-hardware/test/hlk/testref/849bcee9-3305-4889-9645-8c4470f60d9c
    The test checks whether the device declares support to ALUA by checking the INQUIRY TPGS field before additional testing. If the TGPS field is not 0, then the storage devices at least support REPORT TARGET PORT GROUPS, and the Report Target Port Groups test will be done.

Configuration Settings for ALUA Devices - VMware vSphere Blog

    https://blogs.vmware.com/vsphere/2012/02/configuration-settings-for-alua-devices.html
    Feb 03, 2012 · explicit_support: Shows whether or not the device supports explicit ALUA; this option cannot be set by the user as it is a property of the LUN. explicit_allowed: Shows whether or not the user allows the SATP to exercise its explicit ALUA capability if the need arises during path failure. This only matters if the device actually supports explicit ALUA (i.e. explicit_support is 'on').

Updated: What's the deal with EMC CX arrays not supporting ...

    https://www.v-front.de/2012/05/whats-deal-with-emc-cx-arrays-not.html
    May 11, 2012 · Anyway, this is probably the reason why EMC and VMware do not officially support VAAI with ESXi 5.0 on CX arrays. From a customer's point of view this is disappointing, but from EMC's point of view this decision is understandable, because they want to focus on their current products and not waste support resources on somewhat outdated arrays ...

What’s that ALUA exactly? – Yellow Bricks Yellow Bricks

    http://www.yellow-bricks.com/2009/09/29/whats-that-alua-exactly/
    Sep 29, 2009 · My interpretation of ALUA is that you can see any given LUN via both storage processors as active but only one of these storage processors “owns” the LUN and because of that there will be optimized and unoptimized paths. The optimized paths are the ones with a direct path to the storage processor that owns the LUN.

What is Asymmetric Logical Unit Access (ALUA)? - Dell EMC

    https://community.emc.com/docs/DOC-8764
    Oct 27, 2010 · Asymmetric Logical Unit Access (ALUA)? Resolution: ALUA allows you to see any given LUN via both storage processors as active but only one of these storage processors “owns” the LUN and because of that there will be optimized and un-optimized paths. The optimized paths are the ones with a direct path to the storage processor that owns the LUN.

ALUA - SlideShare

    https://www.slideshare.net/AshwinPawar/alua
    Sep 23, 2014 · ALUA 1. Asymmetric Logical Unit Access I/O for Logical Unit „A‟, going directly to Node „A‟ owning the Logical Unit In this acronym, „Logical Unit Access‟ part is well understood but „Asymmetrical‟ at the beginning does make it sound little complicated.



Need to find Lun 0 Does Not Support Alua information?

To find needed information please read the text beloow. If you need to know more you can click on the links to visit sites with more detailed data.

Related Support Info